What this unit covers
MWA G of the RSOS: hydraulic systems (Task G-34), hydrostatic drives (Task G-35) and pneumatic systems (Task G-36). These are original practice notes, not official material of the Red Seal program, and they are based on the RSOS 2023. Service values such as pressures, clearances, torques and intervals always come from the manufacturer's service information.
Principles and formulas
- Flow and pressure: the pump only produces flow; pressure builds when flow meets resistance from a load, a restriction or a relief valve (sub-task G-34.01).
- Cylinder force: Force = pressure × piston area, area = π/4 × bore squared; 14 000 kPa on 0.007854 m² gives 110 kN. The rod side has a smaller area and less force (sub-task G-34.01).
- Hydraulic power: Power = pressure × flow; 17 500 kPa × 0.0015 m³/s = 26.25 kW, and input power = 26.25 / 0.85 = 30.9 kW (sub-task G-34.02).
- Valves: a sequence valve opens at its setting to feed a second branch; a reducing valve lowers one branch pressure; a relief valve limits maximum pressure (sub-task G-34.01).
- Oil samples: taken warm and circulating, from the same valve each time (sub-task G-34.01).
Hydraulic testing and diagnosis
- Flow test: start with the loading valve open, warm the oil, close it slowly to the test pressure and read the flow (sub-task G-34.02).
- All functions or one: low flow at rated speed with normal pressure is internal pump slip (volumetric efficiency); one function only points to its circuit, valve or solenoid voltage (sub-task G-34.02).
- Margin pressure: pump outlet pressure minus load-sense signal pressure (sub-task G-34.02).
- Cavitation: high inlet vacuum that eases as the oil warms means oil too thick to fill the pump; an air leak foams the oil (sub-task G-34.02).
- Low stall pressure: points to a main relief valve opening early or leaking; never set a relief above specification (sub-task G-34.02).
- Start-up: a piston pump case is filled with clean oil and primed (sub-task G-34.03).
Hydrostatic drives
- Swashplate: its tilt sets piston stroke and flow; past centre, flow reverses (sub-task G-35.01).
- Charge circuit: makes up loop leakage and feeds the servo; low charge pressure with a new filter points to the charge pump or charge relief (sub-task G-35.02).
- Flushing valve: lets hot loop oil leave, replaced by cooler charge oil (sub-task G-35.01).
- Symptoms: creeping in neutral is a swashplate not centred; high case drain flow and heat mean pump or motor wear; weakness in one direction only points to that side's crossover relief (sub-task G-35.02).
- Pump flow: displacement × speed × efficiency; 56 cm³ × 2 000 rpm = 112 L/min, × 0.92 = 103 L/min (sub-task G-35.02).
- Service: engine stopped and loop pressure relieved before a line is opened; start-up at low speed, no load, air purged (sub-task G-35.03).
Pneumatic systems
- Stored air: released and isolated before any fitting is opened; a safety valve outlet is never plugged (sub-task G-36.01).
- Slow build-up: without leaks, worn compressor rings (sub-task G-36.02).
- Pressure protection valve: zero at its outlet with the reservoir at cut-out means it is stuck closed (sub-task G-36.02).
- Safety valve setting: above governor cut-out, below the limit of the weakest component (sub-task G-36.03).
- Air dryer: purges at cut-out; a purge valve stuck closed sends water to the reservoirs (sub-task G-36.02).
Sample questions (5)
1. In a hydraulic circuit, what creates system pressure?
- Reservoir oil volume.
- Pump displacement size.
- Resistance to oil flow.
- Hydraulic oil viscosity.
The pump only produces flow; pressure builds when that flow meets resistance from a load, a restriction or a relief valve (sub-task G-34.01). Pump displacement sets how much oil is moved per revolution, not the pressure. Reservoir volume only stores oil, and viscosity changes losses and heat but does not create pressure by itself.
2. A wheel loader's ride control accumulator reads below its specified precharge during a scheduled service. What gas is used to bring it back up?
- Filtered shop air.
- Bottled oxygen.
- Dry nitrogen gas.
- Carbon dioxide.
Dry nitrogen is inert, so it cannot support combustion when it contacts hydraulic oil under compression, and it brings no moisture into the gas side (sub-task G-34.01, accumulators). Filtered shop air and bottled oxygen can mix with oil vapour and burn or explode when compressed quickly. Carbon dioxide is not an accepted precharge gas for accumulators.
3. Which valve lets a second cylinder move only after the first one reaches a set pressure?
- Pressure sequence valve.
- Pressure relief valve.
- Pressure reducing valve.
- Pressure unloading valve.
A sequence valve stays closed until the pressure in the first branch reaches its setting, then opens to feed the second cylinder (sub-task G-34.01). A pressure reducing valve lowers the pressure in one branch, and a relief valve only limits the maximum pressure. An unloading valve sends pump flow to the tank at a set pressure instead of feeding another cylinder.
4. A technician must replace a hose on a circuit that has an accumulator. What must be done first?
- Release and isolate stored pressure.
- Crack the hose fitting to bleed it.
- Drain half of the reservoir oil.
- Warm the oil to operating temperature.
The accumulator can hold oil under pressure after the engine stops, so stored energy is released and isolated first, following the manufacturer's procedure (sub-task G-34.03). Cracking a fitting on a charged line can spray oil or let a hose whip. Warming the oil or draining the reservoir does nothing to remove trapped pressure.
5. What is the best way to collect an oil sample for trend analysis?
- Cold, after the machine sits overnight.
- Warm, from the same sampling valve.
- Warm, right after an oil change.
- Cold, from the reservoir drain plug.
A sample taken with the oil warm and circulating, from the same sampling valve each time, is representative and can be compared from one service to the next (sub-task G-34.01 includes collecting oil samples for analysis). Oil that has sat overnight lets particles and water settle out, so a cold sample misses them, and the drain plug collects settled sludge and water. A sample taken right after an oil change shows mostly new oil and hides the wear trend.